Aisle Containment Components
Doors, roof panels, end-of-row frames and seals for cold-aisle and hot-aisle containment — supplied as project kits to integrators.
- Minimum order
- Per project.
- Lead time
- Confirmed per quotation after layout review.
Containment separates supply and exhaust air so cooling units can run at higher set-points with less fan energy. A containment system is a kit of standard parts adapted to the rack line: end-of-aisle doors (sliding or hinged), roof panels or chimneys, frames and brackets, blanking and brush seals.
We supply containment components and kits to integrators who design the layout. Frames are sheet steel or aluminium profile; roof and door panels are polycarbonate or acrylic, selected to meet the fire requirements of the project and the local authority — ask for the fire classification you need and we confirm which panel materials the manufacturer can document.
Key specifications
| Kit components | End-of-aisle doors (sliding / hinged), roof panels, frames, brackets, sealsSource: datacenterresources.com |
|---|---|
| Frame materials | Steel sheet or aluminium profileSource: datacenterresources.com |
| Panel materials | Polycarbonate or acrylic; fire classification per projectSource: eziblank.com |
| Accessories | Blanking panels, brush panels, rack-gap sealsSource: subzeroeng.com |
| Configuration | Cold-aisle or hot-aisle; adapted to rack height and row length |
Typical, configurable ranges compiled from published manufacturer data. Final values are confirmed per order in the quotation and supporting test documents.
Materials
Steel or aluminium frames; PC or acrylic panels; EPDM or brush seals.
Dimensions & formats
Adapted to rack height, depth and row length from your layout.
Options & customisation
- Door signage, logo panels
- Colour of frames
- Special widths for uneven rows
Applications
- New data halls
- Retrofit containment in legacy rooms
- Colocation suites
- Edge sites with in-row cooling
Ordering information
Minimum order
Per project.
Lead time
Confirmed per quotation after layout review.
Packaging
Crated per aisle, labelled by position.
Loading & shipping
Project freight; loading plan per order.
Aluminium frames into the USA are affected by AD/CVD on Chinese aluminium extrusions; steel frames into the EU fall under CBAM.
Technical documentation
- Kit drawings and parts listsAvailable on request with your RFQ
- Panel material fire dataAs documented by the panel manufacturer
- Installation guideAvailable on request with your RFQ
Frequently asked questions
Cold-aisle or hot-aisle containment?
That is a design decision for your integrator or consultant (room layout, cooling type, fire strategy). We supply parts for either.
What about fire suppression?
Roof designs must suit the fire-suppression strategy (for example drop-away or retractable roofs). Your fire engineer decides; we supply the specified type.
Can you supply only doors?
Yes, components can be ordered individually.